This wiki has undergone a migration to Confluence found Here
<meta name="googlebot" content="noindex">

Difference between revisions of "P515 withdraw fields"

From HL7Wiki
Jump to navigation Jump to search
m
m
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
{{InM Open Action Items}}
+
{{InM Closed Action Items}}
 
'''P515 Withdraw Fields'''
 
'''P515 Withdraw Fields'''
[[category:Version2 Action Items]]
+
 
  
 
==Sponsoring Person==
 
==Sponsoring Person==
Line 10: Line 10:
 
Accepted by INM        on motion by  __/__ (00-00-00)  
 
Accepted by INM        on motion by  __/__ (00-00-00)  
 
==Justification==
 
==Justification==
STF needs the capability to interface the staff digital signature.In the course of developing the US Realm v2.5.1 Lab Result Interoperability Specification, we discovered a number of fields in the chapter 3 segments that meet criteria for withdrawal as specified in chapter 2. We are seeking to have these, in fact, withdrawn as they cannot be updated and thus create maintenance difficulties.
+
In the course of developing the US Realm v2.5.1 Lab Result Interoperability Specification, we discovered a number of fields in the chapter 3 segments that meet criteria for withdrawal as specified in chapter 2. We are seeking to have these, in fact, withdrawn as they cannot be updated and thus create maintenance difficulties.
  
 
This is a joint proposal from Quest Diagnostics and Kaiser Permanente.
 
This is a joint proposal from Quest Diagnostics and Kaiser Permanente.

Latest revision as of 18:41, 14 April 2008


This is a page of type Category:InM Closed Action Items.

P515 Withdraw Fields


Sponsoring Person

 Joann Larson

Description

Withdraw chapter 3 fields meeting criteria for withdrawal.

Disposition =

Accepted by INM on motion by __/__ (00-00-00)

Justification

In the course of developing the US Realm v2.5.1 Lab Result Interoperability Specification, we discovered a number of fields in the chapter 3 segments that meet criteria for withdrawal as specified in chapter 2. We are seeking to have these, in fact, withdrawn as they cannot be updated and thus create maintenance difficulties.

This is a joint proposal from Quest Diagnostics and Kaiser Permanente.

Proposed Solution

The following meet the criteria for withdrawal and should be withdrawn in the next ballot: EVN-1 (V2.3)

PID-2 (V2.3.1)

PID-4 (V2.3.1)

PID-9 (V2.4)

PID-12 (V2.3)

PID-19 (V2.3.1)

PID-20 (v2.5)

PID-28 (V2.4)

PV1-9 (V2.4)

PV1-40 (V2.4)

PV1-52 (V2.4)

AL1-6 (V2.4)

MRG-2 (V2.4)

MRG-4 (V2.4)

PD1-4 (V2.4)