PHER CR ELR R1 XCN.13 length
Submitted by: Riki Merrick Revision date: <<Revision Date>> Submitted date: May 23, 2013 Change request ID: <<Change Request ID>> Standard: ELRtoPHv251 R1 Artifact ID, Name: <<Artifact ID, Name>> Contents [hide] 1 Issue 2 Recommendation 3 Rationale 4 Discussion 5 Recommended Action Items 6 Resolution [edit] Issue
The length of XCN.13 is listed as 2..5 in the guide and refers to the unconstrained HL7 table 203 (Identifier Type) - the smallest value in that table has only 1 character and currently causes an error - example 'U' for 'Unspecified Identifier'.
The same applies for CX.5 and XON.7.
[edit] Recommendation Change length to 1..5 and issue errata to ELR R1, so NIST tool can be updated to reflect that.
[edit] Rationale If a field requires use of an HL7 table, it should support ALL values, hence adjust length accordingly - else constrain the table to exclude the value.
[edit] Discussion
[edit] Recommended Action Items
[edit] Resolution
(Resolution is to be recorded here and in the referenced minutes, which are the authoritative source of resolution). Categories: PHER Open Change Requests | Change Requests for PHER Standards