This wiki has undergone a migration to Confluence found Here
Difference between revisions of "IIWG TCON 2016-12-08"
Jump to navigation
Jump to search
(Created page with "==Agenda== #Opening ##Call to order, introductions, welcome ##Review & approval of the Agenda ##Minutes of the previous meeting. ##Antitrust rules. #Topics to be discussed ...") |
(→Agenda) |
||
(3 intermediate revisions by 2 users not shown) | |||
Line 7: | Line 7: | ||
##Antitrust rules. | ##Antitrust rules. | ||
#Topics to be discussed | #Topics to be discussed | ||
+ | ##Approve [http://gforge.hl7.org/gf/project/fhir/tracker/?action=TrackerItemEdit&tracker_item_id=10273&start=0 Tracker Item 10273] | ||
##Review WGM Schedule | ##Review WGM Schedule | ||
− | ##Discussion on use of "media" for DICOM content | + | ##Discuss May WGM attendence |
+ | ##Discussion on use of "media" for DICOM content ([https://chat.fhir.org/#narrow/stream/implementers/topic/Media.20.26.20Imaging.20Study.20Resource link]). Discussion questions include: | ||
+ | ###Does it make sense to prohibit Media for DICOM content. If you have DICOM content it must be accessed through ImagingStudy/ImagingManifest (and thus, would need a PACS to store the images). | ||
+ | ###Are there use cases where Media might be appropriate across organizations? | ||
+ | ###If a patient walks into their GP’s/PCP’s office with an image on a CD. Is it appropriate to store the image in a Media resource if the PCP doesn’t have a PACS? | ||
+ | ###The URLs in ImagingStudy/ImagingManifest are “undecorated.” What is the appropriate way to record a particular rendering of a DICOM image used in a report, etc.? Should this be Media.content.url with a full rendered WADO-RS URL? The resulting JPEG should be put in Media.content.data? | ||
+ | ###If I need to send a collection of FHIR content, e.g. a report, how does the related imaging travel with it? | ||
+ | ###If there are multiple copies/renderings of the same image in various places, what are the change management issues? Should an image included in a report should remain available in that report regardless of what happens to the source of that image? | ||
+ | ###Are there workflows where you might have a DICOM instance but not the necessary information to put together an ImagingStudy? | ||
+ | ###Should we recommend only rendered “display-ready” content be put in Media, but non-rendered content be accessed via ImagingStudy? | ||
+ | ###Is there a need to cross-reference between a DICOM instance (rendered or not) put in Media and the same instance in an ImagingStudy? | ||
+ | ##Discussion of direction of MHD-I. | ||
+ | |||
#Next meetings | #Next meetings | ||
+ | ##January 5, 2017 at 2:00pm: Teleconference | ||
##January 16-20, 2017: In-person HL7 WG Meeting | ##January 16-20, 2017: In-person HL7 WG Meeting | ||
#Adjournment | #Adjournment |
Latest revision as of 19:10, 8 December 2016
Agenda
- Opening
- Call to order, introductions, welcome
- Review & approval of the Agenda
- Minutes of the previous meeting.
- Antitrust rules.
- Topics to be discussed
- Approve Tracker Item 10273
- Review WGM Schedule
- Discuss May WGM attendence
- Discussion on use of "media" for DICOM content (link). Discussion questions include:
- Does it make sense to prohibit Media for DICOM content. If you have DICOM content it must be accessed through ImagingStudy/ImagingManifest (and thus, would need a PACS to store the images).
- Are there use cases where Media might be appropriate across organizations?
- If a patient walks into their GP’s/PCP’s office with an image on a CD. Is it appropriate to store the image in a Media resource if the PCP doesn’t have a PACS?
- The URLs in ImagingStudy/ImagingManifest are “undecorated.” What is the appropriate way to record a particular rendering of a DICOM image used in a report, etc.? Should this be Media.content.url with a full rendered WADO-RS URL? The resulting JPEG should be put in Media.content.data?
- If I need to send a collection of FHIR content, e.g. a report, how does the related imaging travel with it?
- If there are multiple copies/renderings of the same image in various places, what are the change management issues? Should an image included in a report should remain available in that report regardless of what happens to the source of that image?
- Are there workflows where you might have a DICOM instance but not the necessary information to put together an ImagingStudy?
- Should we recommend only rendered “display-ready” content be put in Media, but non-rendered content be accessed via ImagingStudy?
- Is there a need to cross-reference between a DICOM instance (rendered or not) put in Media and the same instance in an ImagingStudy?
- Discussion of direction of MHD-I.
- Next meetings