This wiki has undergone a migration to Confluence found Here
OO CR142 - RP and ED data types
Jump to navigation
Jump to search
Return to OO Change Requests page.
Submitted by: Eric Haas | Revision date: <<Revision Date>> |
Submitted date: November 1, 2013 | Change request ID: OO CR142 |
Standard/IG: Implementation Guide | Artifact ID, Name: Remove reference to RP and ED datatypes |
Issue
NOTE: this issue may be resolved by the value set project. May have already been resolved. The RP and ED datatype are optional datatypes for OBX.5 in the IG, therefore it is unnecessary to list the HL7 tables 0834, 0291, in the IG because these table only apply to these datatypes. Also usage and comment URI in table 0301 currently refers only to the RP data type.
Recommendation
- 1) Remove HL7 tables 0834, 0291
- 2) Change the usage for URI in table 0301 to C(X/O) and change the comment to "Condition Predicate: If Component GU is used on the field using this value set"
Rationale
The RP and ED datatype are optional datatypes for OMX.5 in the IG, therefore it is unnecessary to list the HL7 tables 0834, 0291 and refer to the RP datatype in the URI row in table 0301.
Discussion
Recommended Action Items
Resolution
2013-12-12 Motion to accept recommendation #1 Eric Haas, Mark Jones
Against: 0 Abstain: 0 For: 8