This wiki has undergone a migration to Confluence found Here
QRDA Errata
Jump to navigation
Jump to search
To return to the >> Clinical Quality Information Work Group Page
To return to the >> Structured Documents Work Group Page
Approved Errata
SEE THE QRDA CATEGORY I DSTU WEBSITE FOR A FULL LIST OF QRDA ERRATA: http://www.hl7.org/dstucomments/showdetail.cfm?dstuid=80
- There are 4 statement in the IG where the unit attributre is incorrectly constrained to the literal value "1":
- This value SHALL contain exactly one [1..1] @unit="1", which SHALL be selected from ValueSet AgePQ_UCUM 2.16.840.1.113883.11.20.9.21 DYNAMIC (CONF:7618).
- The doseQuantity, if present, SHOULD contain zero or one [0..1] @unit="1", which SHALL be selected from ValueSet UCUM Units of Measure (case sensitive) 2.16.840.1.113883.1.11.12839 DYNAMIC (CONF:7526).
- The rateQuantity, if present, SHALL contain exactly one [1..1] @unit="1", which SHALL be selected from ValueSet UCUM Units of Measure (case sensitive) 2.16.840.1.113883.1.11.12839 DYNAMIC (CONF:7525).
- This value SHALL contain exactly one [1..1] @unit="1", which SHALL be selected from ValueSet DayWkPQ_UCUM 2.16.840.1.113883.11.20.9.40 DYNAMIC (CONF:16534).
- The correct constraints are as follows:
- This value SHALL contain exactly one [1..1] @unit, which SHALL be selected from ValueSet AgePQ_UCUM 2.16.840.1.113883.11.20.9.21 DYNAMIC (CONF:7618).
- The doseQuantity, if present, SHOULD contain zero or one [0..1] @unit, which SHALL be selected from ValueSet UCUM Units of Measure (case sensitive) 2.16.840.1.113883.1.11.12839 DYNAMIC (CONF:7526).
- The rateQuantity, if present, SHALL contain exactly one [1..1] @unit, which SHALL be selected from ValueSet UCUM Units of Measure (case sensitive) 2.16.840.1.113883.1.11.12839 DYNAMIC (CONF:7525).
- This value SHALL contain exactly one [1..1] @unit, which SHALL be selected from ValueSet DayWkPQ_UCUM 2.16.840.1.113883.11.20.9.40 DYNAMIC (CONF:16534).
- Inaccurate CPT full name in Table 81: Encounter Type Value Set
- Original text: "the Current Procedure and Terminology"
- Corrected text: "the Current Procedural Terminology"
- Device Adverse Event [2.16.840.1.113883.10.20.24.3.5] – has a SHALL [1..1] Patient Preference and Provider Preference. Both of these should be MAY [0..1]
- Encounter Performed [2.16.840.1.113883.10.20.24.3.23] -
- Change this: MAY contain zero or one [0..1] Facility Location (templateId:2.16.840.1.113883.10.20.24.3.100).
- To this: MAY contain zero or more [0..*] Facility Location (templateId:2.16.840.1.113883.10.20.24.3.100).
- Intervention Performed [2.16.840.1.113883.10.20.24.3.32] – example is missing the required effectiveTime/high
Errata to be reviewed by SDWG
- (none)