'''SEE THE QRDA CATEGORY I DSTU WEBSITE FOR A FULL LIST OF QRDA ERRATA:''' http://www.hl7.org/dstucomments/showdetail.cfm?dstuid=80 <br>
 
'''SEE THE QRDA CATEGORY I DSTU WEBSITE FOR A FULL LIST OF QRDA ERRATA:''' http://www.hl7.org/dstucomments/showdetail.cfm?dstuid=80 <br>
 
 
* There are 4 statement in the IG where the unit attributre is incorrectly constrained to the literal value "1":
 
**This value SHALL contain exactly one [1..1] @unit="1", which SHALL be selected from ValueSet AgePQ_UCUM 2.16.840.1.113883.11.20.9.21 DYNAMIC (CONF:7618).
 
**The doseQuantity, if present, SHOULD contain zero or one [0..1] @unit="1", which SHALL be selected from ValueSet UCUM Units of Measure (case sensitive) 2.16.840.1.113883.1.11.12839 DYNAMIC (CONF:7526).
 
**The rateQuantity, if present, SHALL contain exactly one [1..1] @unit="1", which SHALL be selected from ValueSet UCUM Units of Measure (case sensitive) 2.16.840.1.113883.1.11.12839 DYNAMIC (CONF:7525).
 
**This value SHALL contain exactly one [1..1] @unit="1", which SHALL be selected from ValueSet DayWkPQ_UCUM 2.16.840.1.113883.11.20.9.40 DYNAMIC (CONF:16534).
 
*The correct constraints are as follows:
 
**This value SHALL contain exactly one [1..1] @unit, which SHALL be selected from ValueSet AgePQ_UCUM 2.16.840.1.113883.11.20.9.21 DYNAMIC (CONF:7618).
 
**The doseQuantity, if present, SHOULD contain zero or one [0..1] @unit, which SHALL be selected from ValueSet UCUM Units of Measure (case sensitive) 2.16.840.1.113883.1.11.12839 DYNAMIC (CONF:7526).
 
**The rateQuantity, if present, SHALL contain exactly one [1..1] @unit, which SHALL be selected from ValueSet UCUM Units of Measure (case sensitive) 2.16.840.1.113883.1.11.12839 DYNAMIC (CONF:7525).
 
**This value SHALL contain exactly one [1..1] @unit, which SHALL be selected from ValueSet DayWkPQ_UCUM 2.16.840.1.113883.11.20.9.40 DYNAMIC (CONF:16534).
 
 
 
*Inaccurate CPT full name in Table 81: Encounter Type Value Set
 
**Original text: "the Current Procedure and Terminology"
 
**Corrected text: "the Current Procedural Terminology"
 
 
 
* Device Adverse Event [2.16.840.1.113883.10.20.24.3.5] – has a SHALL [1..1] Patient Preference and Provider Preference. Both of these should be MAY [0..1]
 
 
 
* Encounter Performed [2.16.840.1.113883.10.20.24.3.23] -
 
** Change this: MAY contain '''zero or one [0..1]''' Facility Location (templateId:2.16.840.1.113883.10.20.24.3.100).
 
** To this: MAY contain '''zero or more [0..*]''' Facility Location (templateId:2.16.840.1.113883.10.20.24.3.100).
 
 
 
* Intervention Performed [2.16.840.1.113883.10.20.24.3.32] – example is missing the required effectiveTime/high
 