This resource identifies an instance of a manufactured thing that is used in the provision of healthcare without being substantially changed through that activity. The device may be a machine, an insert, a computer, an application, etc.  This includes durable (reusable) medical equipment as well as disposable equipment used for diagnostic, treatment, and research for healthcare and public health.
 
This resource identifies an instance of a manufactured thing that is used in the provision of healthcare without being substantially changed through that activity. The device may be a machine, an insert, a computer, an application, etc.  This includes durable (reusable) medical equipment as well as disposable equipment used for diagnostic, treatment, and research for healthcare and public health.
  
Primarily used for recording which device performed an action and can also be used to track device location.
+
Primarily used for recording which device performed an action and can also be used to track device location.  Can also be used for prescribing and dispensing devices for patient use.
  
 
==RIM scope==
 
==RIM scope==
Line 71: Line 71:
 
* Have the characteristics of high cohesion & low coupling – need to explore whether coupling is good some places, not elsewhere – layers from Bo’s document  
 
* Have the characteristics of high cohesion & low coupling – need to explore whether coupling is good some places, not elsewhere – layers from Bo’s document  
 
  -->
 
  -->
Devices are used throughout healthcare for the precise (and imprecise) measurements related to diagnostics and treatments, to deliver theraputic drugs and other forms of treatment, for use in surgical procedures, and used throughout research scenarios.  As such, a device resource is required for the information components.
+
Devices are used throughout healthcare for the precise (and imprecise) measurements related to diagnostics and treatments, to deliver therapeutic drugs and other forms of treatment, for use in surgical procedures, and used throughout research scenarios.  As such, a device resource is required for the information components.
  
 
==Expected implementations==
 
==Expected implementations==
  
 
<!-- For resources not deemed "key", what interest is there by implementers in using this particular resource.  (Should ideally have multiple independent implementations) -->
 
<!-- For resources not deemed "key", what interest is there by implementers in using this particular resource.  (Should ideally have multiple independent implementations) -->
future
+
Needed as part of CCDA
  
 
==Content sources==
 
==Content sources==
Line 86: Line 86:
 
*HL7 v3 Laboratory Standard - Normative
 
*HL7 v3 Laboratory Standard - Normative
 
*HL7 v3 Implantable Devices Standard - Normative
 
*HL7 v3 Implantable Devices Standard - Normative
*HL7 v2.x
+
*HL7 v2.x (including SFT segment)
 +
 
 +
==Example Scenarios==
 +
 
 +
<!-- Provide a listing of the types of scenarios to be represented in the examples produced for this resource.  They should demonstrate the full scope of the resource and allow exercising of the resources capabilities (full element coverage, inclusion & omission of optional elements, repeating and singleton repeating elements, etc.) -->
  
 
==Resource Relationships==
 
==Resource Relationships==
Line 120: Line 124:
 
*Lorraine Constable
 
*Lorraine Constable
 
*Patrick Loyd
 
*Patrick Loyd
 +
 +
==Issues==
 +
* What's the determinerCode?  instance, kind or don't care?  If not fixed, is there a way to infer it?
 +
* Need example scenarios
 +
* Look at NCPDP and OpenEHR as possible sources for device as well (not sure if they have coverage or not)
 +
* Need to explain the types of relationships to the listed resources

Revision as of 18:09, 12 June 2013



Device

Owning committee name

Orders & Observations WG

Interested Work Groups

  • Laboratory (and Lab Automation)
  • Anatomic Pathology
  • Clinical Genomics
  • Imaging Integration
  • Pharmacy
  • Public Health and Emergency Response
  • Devices

FHIR Resource Development Project Insight ID

952

Scope of coverage

DEFINITION (DEVICES): This resource identifies an instance of a manufactured thing that is used in the provision of healthcare without being substantially changed through that activity. The device may be a machine, an insert, a computer, an application, etc. This includes durable (reusable) medical equipment as well as disposable equipment used for diagnostic, treatment, and research for healthcare and public health.

Primarily used for recording which device performed an action and can also be used to track device location. Can also be used for prescribing and dispensing devices for patient use.

RIM scope

  • Entity: ManufacturedMaterial (Enity.classCode="MMAT")
  • Entity: Devices (Entity.code=DeviceGenericType)

Resource appropriateness

Devices are used throughout healthcare for the precise (and imprecise) measurements related to diagnostics and treatments, to deliver therapeutic drugs and other forms of treatment, for use in surgical procedures, and used throughout research scenarios. As such, a device resource is required for the information components.

Expected implementations

Needed as part of CCDA

Content sources

  • HL7 v3 Laboratory Standard - Normative
  • HL7 v3 Implantable Devices Standard - Normative
  • HL7 v2.x (including SFT segment)

Example Scenarios

Resource Relationships

  • Order
  • DiagnosticOrder
  • DiagnosticReport
  • Procedure
  • ImagingStudy (future)
  • Specimen
  • Location
  • Medication
  • Product

Timelines

  • Proposal Approved by WG: Aug 2013, then updated and re-approved May 2013 at WGM
  • Planned Ballot: September 2013

gForge Users

  • Lorraine Constable
  • Patrick Loyd

Issues

  • What's the determinerCode? instance, kind or don't care? If not fixed, is there a way to infer it?
  • Need example scenarios
  • Look at NCPDP and OpenEHR as possible sources for device as well (not sure if they have coverage or not)
  • Need to explain the types of relationships to the listed resources