This wiki has undergone a migration to Confluence found Here
<meta name="googlebot" content="noindex">

Difference between revisions of "Confidentiality code support in ClinicalStatement choices"

From HL7Wiki
Jump to navigation Jump to search
(New page: {{CDA R3 Open Proposals}} Return to SDTC page; Return to CDA R3 Formal Proposals page. {|width=100% cellspacing=0 cellpa...)
 
 
(4 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{CDA R3 Open Proposals}}
+
{{CDA R3 Closed Proposals}}
  
 
Return to [[Structured Documents TC|SDTC]] page; Return to [[:category:CDA R3 Formal Proposals|CDA R3 Formal Proposals]] page.
 
Return to [[Structured Documents TC|SDTC]] page; Return to [[:category:CDA R3 Formal Proposals|CDA R3 Formal Proposals]] page.
Line 5: Line 5:
 
{|width=100% cellspacing=0 cellpadding=2 border=1
 
{|width=100% cellspacing=0 cellpadding=2 border=1
 
|| '''Submitted by:''' Ioana Singureanu
 
|| '''Submitted by:''' Ioana Singureanu
|| '''Revision date:''' <<Revision Date>>
+
|| '''Revision date:''' 12/1/2009
 
|-
 
|-
 
|| '''Submitted date:''' 11/17/2009
 
|| '''Submitted date:''' 11/17/2009
Line 14: Line 14:
 
== Issue ==
 
== Issue ==
 
Currently there is no way to specify the confidentiality and sensitivity of a act, observation, procedure, etc. choice in a ClinicalStatement. This information is often required in specifying the Consent Directive or Privacy Policy.  
 
Currently there is no way to specify the confidentiality and sensitivity of a act, observation, procedure, etc. choice in a ClinicalStatement. This information is often required in specifying the Consent Directive or Privacy Policy.  
 +
===Severity:High===
 +
High: The workaround is an ambiguous use of "Precondition" in place of a security indicator.
 +
[[Community-Based Collaborative Care|CBCC WG Wiki]]
  
  
 
== Recommendation ==
 
== Recommendation ==
 
* Add "confidentialityCode" property to the classes avaialable as choices in POCD_MT000040.Entry (clinicalStatement)
 
* Add "confidentialityCode" property to the classes avaialable as choices in POCD_MT000040.Entry (clinicalStatement)
* Add "senstivityCode" - if available in the current version of the RIM
 
  
 
== Rationale ==
 
== Rationale ==
Line 25: Line 27:
 
== Discussion ==
 
== Discussion ==
 
The item was introduced during the SDWG meeting - Nov. 17th, 2009.
 
The item was introduced during the SDWG meeting - Nov. 17th, 2009.
 +
This proposal would replace the current workaround using "Precondition":
 +
<precondition typeCode="PRCN">
 +
<criterion classCode="OBS" moodCode="EVN.CRT">
 +
<!-- Sensitivity - sometimes set  on client's
 +
            instruction -->
 +
<code code="N" codeSystemName="HL7Confidentiality"
 +
                codeSystem="2.16.840.1.113883.5.25"
 +
                displayName="Normal"/>
 +
</criterion>
 +
</precondition>
  
 +
with this RIM-based attribute:
 +
 +
<confidentialityCode code="N"/>
  
 
== Recommended Action Items ==
 
== Recommended Action Items ==
Line 31: Line 46:
  
 
== Resolution ==
 
== Resolution ==
(Resolution is to be recorded here and in the referenced minutes, which are the authoritative source of resolution).
+
April 13, 2010 SDWG: Comes along with decision to use RIM as right side of CDA R3 (therefore approved). Opposed: 0; Abstain: 0; In favor: 7.

Latest revision as of 21:38, 13 April 2010


Return to SDTC page; Return to CDA R3 Formal Proposals page.

Submitted by: Ioana Singureanu Revision date: 12/1/2009
Submitted date: 11/17/2009 Change request ID: <<Change Request ID>>

Issue

Currently there is no way to specify the confidentiality and sensitivity of a act, observation, procedure, etc. choice in a ClinicalStatement. This information is often required in specifying the Consent Directive or Privacy Policy.

Severity:High

High: The workaround is an ambiguous use of "Precondition" in place of a security indicator. CBCC WG Wiki


Recommendation

  • Add "confidentialityCode" property to the classes avaialable as choices in POCD_MT000040.Entry (clinicalStatement)

Rationale

Needed for Consent Directive representations.

Discussion

The item was introduced during the SDWG meeting - Nov. 17th, 2009. This proposal would replace the current workaround using "Precondition": <precondition typeCode="PRCN">

<criterion classCode="OBS" moodCode="EVN.CRT">

</criterion>
</precondition>

with this RIM-based attribute:

<confidentialityCode code="N"/>

Recommended Action Items

Resolution

April 13, 2010 SDWG: Comes along with decision to use RIM as right side of CDA R3 (therefore approved). Opposed: 0; Abstain: 0; In favor: 7.