This wiki has undergone a migration to Confluence found Here
<meta name="googlebot" content="noindex">

Igor Sirkovich, 2008 use of MaterialKind and MaterialKind2

From HL7Wiki
Jump to navigation Jump to search

Hi Igor,

I suggest you direct your request to the INM (Infrastructure & Messaging) Technical Committee. They are responsible for all CMETs and Shared messages.

Regards,

John Kufuor-Boakye Gordon Point Informatics 780-439-3066 (desk phone) 780-951-4376 (cell)


Original Message-----

From: Sirkovich, Igor (MOH) [1] Sent: Wednesday, July 30, 2008 2:19 PM To: John Kufuor-Boakye; Hugh_Glover; patientcare@lists.hl7.org Subject: RE: AdministerableMaterialKind - REPC_HD000200UV - A_CarePlan


Thanks John!

I agree that replication of the way the device is used in substance administration, as modeled in Pharmacy DMIM, in the Care Plan RMIM would be the best solution. However we have found one issue with the AssignedDevice universal (COCT_RM090300UV) CMET that is used in the Pharmacy DMIM - there is no Entity Code defined for Device. Thus, there is no way to indicate what kind of device was used for substance administration, e.g. Syringe, Pen, AutoInjector, etc...

I suggest we need to submit a request to include the Device codeEntity in COCT_RM090300UV. Do you know which working committee is responsible for this CMET?

Thanks, Igor


Original Message-----

From: John Kufuor-Boakye [2] Sent: Wednesday, July 30, 2008 2:57 PM To: Sirkovich, Igor (MOH); 'Hugh_Glover'; patientcare@lists.hl7.org Subject: RE: AdministerableMaterialKind - REPC_HD000200UV - A_CarePlan

Igor,

What Hugh is referring to on the Pharmacy DMIM separates the participation of a consumable (as depicted on the Patient Care's Care Plan RMIM) from the participation of a device in SubstanceAdministrationProcess (either as the dispensed item or as the device use in administration).

I did exchange notes with the Patient Care co-chairs last night on your comment/issue, and indicated that we would take up your comment as a normal Care Plan DSTU comment and deal with it in Vancouver.

Meanwhile, the thing to do is not to abstract the codeEntity upward to MaterialEntityEntityClassType (that would include Devices as consumable AdministrableMaterial). The way forward would be to replicate in the Care Plan RMIM, the device structure as modeled in Pharmacy DMIM. That way, the dispensing of a device or the use of a device in substance administration can be clearly identified in the Care Plan (if necessary).

Regards,

John Kufuor-Boakye 780-439-3066 (desk phone) 780-951-4376 (cell)


Original Message-----

From: owner-patientcare@lists.hl7.org [3] On Behalf Of Sirkovich, Igor (MOH) Sent: Wednesday, July 30, 2008 12:11 PM To: Hugh_Glover; patientcare@lists.hl7.org Subject: RE: AdministerableMaterialKind - REPC_HD000200UV - A_CarePlan


Thanks Hugh!

We did have a look at the pharmacy DMIM PORX_DM000000 and the way it links a Device to a Substance Administration would work well for us, but unfortunately this link is not part of the CarePlan, which we are using for our e-Referrals.

Why aren't you sure widening codeEntity of the MaterialKind to allow any MaterialEntityClassType is right? I think it would make the Care Plan model flexible enough to meet various business needs.

Regards, Igor


Original Message-----

From: Hugh_Glover [4] Sent: Tuesday, July 29, 2008 7:24 PM To: Sirkovich, Igor (MOH); "'patientcare'" Subject: RE: AdministerableMaterialKind - REPC_HD000200UV - A_CarePlan

I've not got any of this in front of me, but ExposureAgent sounds wrong; but I'm not sure widening it to cover anything is right either. If you look at the pharmacy DMIM PORX_DM000000 you will see a device represented somewhere at the top of one of the acts (sorry - from memory). This is specifically there to represent the device in the case you are talking about. This is a good place to start to see if the PatientCare model covers what you need. Regards Hugh


Original Message-----

From: owner-patientcare@lists.hl7.org [5] On Behalf Of Sirkovich, Igor Sent: 30 July 2008 00:19 To: patientcare Subject: AdministerableMaterialKind - REPC_HD000200UV - A_CarePlan

Hello,

Does anyone why codeEntity of the MaterialKind and MaterialKind2 in REPC_HD000200UV - A_CarePlan is bounded to ExposureAgentEntityType? Wouldn't it make more sense to bound it to a broader MaterialEntityClassType?

ExposureAgentEntityType indicates the material to which the patient was exposed which is believed to be related to the adverse reaction. We have a business requirement to indicate a Medical Device that was used for the substance administration.

Thanks,

Igor Sirkovich

Information Architect, HL7 & Integration CC e-Health Standards Team Continuing Care e-Health