Section 3.12 Vital Signs

  • Section 3.12.2 contains a sentence "Vital signs are represented like other results (as defined in section 3.13 Results), with additional vocabulary constraints", which should be changed to "Vital signs are represented like other results (as defined in section 3.13 Results)".


Section 7.1 Sample

  • The sample instance contains an incorrect representation of Guarantor, and the following snippet should be removed:

<participant typeCode="IND"> <associatedEntity classCode="GUAR"> <id root="4ff51570-83a9-47b7-91f2-93ba30373141"/> <addr> <streetAddressLine>17 Daws Rd.</streetAddressLine> <city>Blue Bell</city> <state>MA</state> <postalCode>02368</postalCode> </addr> <telecom value="tel:(888)555-1212"/> <associatedPerson> <name> <given>Kenneth</given> <family>Ross</family> </name> </associatedPerson> </associatedEntity> </participant>


  • The CCD rendering style sheet incorrectly renders the above snippet as the Guardian. Per CONF-109 ("A patient guardian SHALL be represented with ClinicalDocument / recordTarget / patientRole / patient / guardian"), the style sheet should look to ClinicalDocument / recordTarget / patientRole / patient / guardian for rendering guardian information.