This wiki has undergone a migration to Confluence found Here
<meta name="googlebot" content="noindex">

EMS CDA Implementation Guide Errata

From HL7Wiki
Revision as of 16:59, 27 September 2016 by Jlyle (talk | contribs) (→‎NEMSIS eHistory.07 (Environmental/Food Allergies))
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Back to EMS Projects

Appendices

Appendices included in R1 ballot not published in R1 guide. They are available in the R2 guide.

Example for Current Medication (2.16.840.1.1133883.17.3.10.1.77)

         <entry>
           <substanceAdministration classCode="SBADM" moodCode="EVN">
             <templateId root="2.16.840.1.1133883.17.3.10.1.77"/>
             <consumable typeCode="CSM">
               <manufacturedProduct classCode="MANU">
                 <manufacturedMaterial classCode="MMAT" determinerCode="KIND">
                   
                 </manufacturedMaterial>
               </manufacturedProduct>
             </consumable>
           </substanceAdministration>
         </entry>

Constraint for EMS Medications Administered Section

  • MAY contain zero or one [0..1] component (CONF:10015)

should be

  • SHALL contain one or more [1..*] component (CONF:10015)

NEMSIS eHistory.07 (Environmental/Food Allergies)

  • Problem
    • PCR R1 value set provided as answer to LOINC question 69748-2 is no longer correct. NEMSIS 3.4 uses the SNOMED CT list available at here.
    • Further, LOINC has deprecated 69748-2
  • Current advice
    • For NEMSIS 3.4, use PCR R2
    • Use LOINC 79151-7 for question.
    • Bind to SNOMED CT, with SHOULD strength. Refer to NEMSIS list URL.