PHER CR ELR IG OBR25 ValueSet Problem
Return to PHER page; Return to Change Requests for PHER Standards page.
See Change Requests for PHER Standards for instructions on using this form. Failure to adhere to these instructions may result in delays. Editing of formal proposals is restricted to the submitter and PHER co-chairs. Other changes will be undone. Comments can be captured in the associated discussion page.
(An announcement of this proposal must be submitted to the PHER list to be formally submitted.)
Submitted by: Eric Haas | Revision date: <<Revision Date>> |
Submitted date: 2011-01-21 | Change request ID: CR-06 |
Standard: ELR IG | Artifact ID, Name: ELR IG |
Issue
OBR25 value set is listed as “V2 Result Status Value Set” but is not defined in table 6-1 in the Guide.
Recommendation
Change Value set to HL7 Table0123 and add to table 6-1.
Rationale
Value set for OBR25 is HL70123 in 2.5.1 Standard.
Discussion
Recommended Action Items
Resolution
Persuasive. Included requested changes in ELR release 1 Errata.