This wiki has undergone a migration to Confluence found Here
<meta name="googlebot" content="noindex">

Difference between revisions of "OO CR098 - XPN Flavors"

From HL7Wiki
Jump to navigation Jump to search
(Created page with "{{OO Open Change Requests}} {{OO Open LRI IG Change Requests}} Return to OO Change Requests page. {|width=100% cellspacing=0 cellpadding=2 borde...")
 
Line 29: Line 29:
  
 
== Resolution ==
 
== Resolution ==
 +
* 4 September 2012
 +
** Motion by Riki Merrick, to keep XPN-7 RE. Seconded by Scott Robertson,
 +
** Discussion pointed out that the requirement on the EHR makes sense, but on the Lab particularly when the name may have been manually entered without knowledge what the name represented. Lab systems often only support one name therefore may not have the concept of name type.
 +
** Against: 0 Abstain: 1 Favor: 4

Revision as of 20:58, 4 September 2012

Return to OO Change Requests page.

Submitted by: Revision date: <<Revision Date>>
Submitted date: Change request ID:
Standard/IG: Implementation Guide Artifact ID, Name:


Issue

Recommendation

Rationale

Discussion

Recommended Action Items

Resolution

Return to OO Change Requests page.

Submitted by: Ken McCaslin Revision date: <<Revision Date>>
Submitted date: 30 August 2012 Change request ID: OO CR098 - XPN-7 Change from RE to R
Standard/IG: Implementation Guide Artifact ID, Name: <<Artifact ID, Name>>

Issue

On review with the LOI IG, it is believed that the LRI IG should have the XPN-7 changed from RE to R so that it is clear what how the name should be represented.

Recommendation

Suggest to hyperlink from Data Type in each table to the appropriate data types as part of official publication.

Rationale

Discussion

Recommended Action Items

Resolution

  • 4 September 2012
    • Motion by Riki Merrick, to keep XPN-7 RE. Seconded by Scott Robertson,
    • Discussion pointed out that the requirement on the EHR makes sense, but on the Lab particularly when the name may have been manually entered without knowledge what the name represented. Lab systems often only support one name therefore may not have the concept of name type.
    • Against: 0 Abstain: 1 Favor: 4