− | + | The test roles for this track are based on the IHE PCC PMDT Actors below: | |
− | + | <div style="display: inline; width: 600px; float: right;"></div> | |
− | ===Point-of-Care Medical Device | + | [[File:Actors-pmdt.png|490 px]] |
− | *Point-of-care client; it registers medical device, creates/updates point-of-care procedure information, query patient based on identifier scanned at the point-of-care | + | |
− | === | + | ===Point-of-Care Medical Device Reporter=== |
− | *FHIR server, exposes Device, Procedure - references Patient | + | *Point-of-care client; it registers medical device, creates/updates point-of-care procedure information, query patient based on identifier scanned at the point-of-care. This role is played by an system used to track information about medical devices used at the point-of-care. The device and procedure information are populated at the point-of-care using scanned (AIDC) UDI and patient identifier to simplify the accurate tracking of this information. |
+ | ===Medical Device Server=== | ||
+ | *FHIR server, exposes Device, Procedure - references Patient. It is used to persist device and procedure information originating at the point of care. This information is made available to other information systems in the enterprise. This role may be played by a Medical Device Registry or an EHR system. | ||
+ | ===Medical Device Requester=== | ||
+ | *This role is played by any information system that requires to compile a implantable device list for patient, evaluate outcomes based on device type (i.e. DI), respond manufacturers' recalls, and address patient safety events. | ||
+ | |||
==Scenarios== | ==Scenarios== | ||
The following is a summary test cases proposed for | The following is a summary test cases proposed for |
Revision as of 02:48, 5 September 2017
Track Name
Point-of-care Medical Device and Implantable Tracking
Submitting WG/Project/Implementer Group
This track provides a set of simple test cases for Tracking Medical Devices (i.e. diagnostic, therapeutic, monitoring) and Implantables (biologics/tissue/cells and non-biologics/life-supporting/life-sustaining) at point of care addresses current problems relate to information accuracy and it provides procedure contextual information. This track specifies test cases related FHIR STU3 Procedure and Device resources used to report information from the point-of-care to enterprise system consistent with the IHE PCC Point-of-care Medical Device Tracking Supplement.
Justification
- Implantable medical devices are costly and concerns about illegitimate (i.e., counterfeit, stolen) products has become a global issue
- Post-market surveillance of implantable medical devices can be challenging
- Implantable medical device adverse events and recalls pose a patient safety issue
- Acquiring medical device data used at the point-of-care is difficult to retrieve for reuse at a later time
- Closes the loop on data acquisition at the point-of-care to support reporting of medical device data
- Medical device data used for:
- Continuum of care (e.g., Discharge Summary, Referrals)
- Registries (e.g., Total Joint Registry)
- Payers (e.g., government provided, private insurance)
- Can associate a medical device used for monitoring a disease or symptom of a disease (e.g., vital sign monitors, pulse oximeters, blood glucose monitors) to a patient for querying the device or procedure using the UDI
- Medical device data used for:
- Increase patient safety
- Traceability of medical devices (avoid use of counterfeit or illegitimate products)
- Quality issues identified (e.g., recalls, adverse events)
- Increase accurate medical device data capture at the point-of-care
- Eliminates human error from manual medical device data entry
Proposed Track Lead
Ioana Singureanu, VA/BZI, Skype: ioanasingureanu See Connectathon_Track_Lead_Responsibilities
Expected participants
- Department of Veterans Affairs
- Magpie360
- Eversolve, LLC
Roles
The test roles for this track are based on the IHE PCC PMDT Actors below:
Point-of-Care Medical Device Reporter
- Point-of-care client; it registers medical device, creates/updates point-of-care procedure information, query patient based on identifier scanned at the point-of-care. This role is played by an system used to track information about medical devices used at the point-of-care. The device and procedure information are populated at the point-of-care using scanned (AIDC) UDI and patient identifier to simplify the accurate tracking of this information.
Medical Device Server
- FHIR server, exposes Device, Procedure - references Patient. It is used to persist device and procedure information originating at the point of care. This information is made available to other information systems in the enterprise. This role may be played by a Medical Device Registry or an EHR system.
Medical Device Requester
- This role is played by any information system that requires to compile a implantable device list for patient, evaluate outcomes based on device type (i.e. DI), respond manufacturers' recalls, and address patient safety events.
Scenarios
The following is a summary test cases proposed for
- Register (create) device record using
- UDI and DI only
- UDI and DI and optional attributes
- Start procedure...
- with externally referenced device
- Complete procedure
- with externally referenced device
- Complete implantable procedure
- with externally referenced device
- with contained device reference
- Search procedures
- by patient
- by optional search parameter
- search devices
- by patient
- by DI
Register Medical Device or Implantable from the point-of-care
- Action: Create a Device resource (using POST/update), set
Device.id
to 'GUID',Device.udi.carrierAIDC
to the base64-encoded, 'scanned UDI', setDevice.status
to 'active'. Set theDevice.patient
references the previously retrievedPatient
(see 'Precondition'). - Precondition: Query Patient service using the
Patient.identifier
scanned at the point-of-care - Success Criteria:Search
Device
by 'udi-carrier' (expression:Device.udi.carrierHRF | Device.udi.carrierAIDC
). - Bonus point: specify optional data elements (S, 0..) of the
Device
resource.
Complete an Implantable Procedure
- Action:
- Precondition:
- Success Criteria: