[http://wiki.hl7.org/index.php?title=Harmonization_of_Health_Quality_Information_models Back to Harmonization of Health Quality Information Models Page]<br><br>
 
[http://wiki.hl7.org/index.php?title=Harmonization_of_Health_Quality_Information_models Back to Harmonization of Health Quality Information Models Page]<br><br>
Reviewed by the CQI Workgroup on March 23 based on content posted to the CQI Workgroup document site. Updates based on that discussion and additional considerations entered on this wiki on 18 April 2018<br><br>
+
The CQI Workgroup reviewed this content in April 2018 based on QDM version 5.3. The content has been updated to reflect a change in QDM version 5.4. QDM version 5.4 removes the previous QDM datatypes "Communication, Patient to Provider", "Communication, Provider to Patient", and "Communication, Provider to Provider". QDM version 5.4 creates a new QDM datatype, "Communication, Performed".  The previous QDM datatype mapping are retained for historical review. <br><br>
QDM defines Communication as the transmission, receipt, or acknowledgement of information sent from a source to a recipient, such as from one clinician to another regarding findings, assessments, plans of care, consultative advice, instructions, educational resources, etc. It also may include the receipt of response from a patient with respect to any aspect of the care provided. Furthermore, it may include the conveying of information from provider to patient (e.g., results, findings, plans for care, medical advice, instructions, educational resources, appointments). A time and date stamp is required. QDM defines three contexts for communication: Communication, Patient to Provider; Communication, Provider to Patient; Communication, Provider to Provider. For the CQI Work Group, please consider what is intended by the concept of communication as it is identified in FHIR / QI Core, and whether that matches to the intent in QDM.<br><br>
+
QDM defines Communication as the transmission, receipt, or acknowledgement of information sent from a source to a recipient, such as from one clinician to another regarding findings, assessments, plans of care, consultative advice, instructions, educational resources, etc. It also may include the receipt of response from a patient with respect to any aspect of the care provided. Furthermore, it may include the conveying of information from provider to patient (e.g., results, findings, plans for care, medical advice, instructions, educational resources, appointments). A time and date stamp is required. QDM defines on QDM datatype, Communication, Performed.<br><br>
 
'''''[http://hl7.org/fhir/communication.html FHIR Communication Resource]'''''<br>
 
'''''[http://hl7.org/fhir/communication.html FHIR Communication Resource]'''''<br>
 
This resource is a record of a communication. A communication is a conveyance of information from one entity, a sender, to another entity, a receiver. The sender and receivers may be patients, practitioners, related persons, organizations, or devices. Communication use cases include:
 
This resource is a record of a communication. A communication is a conveyance of information from one entity, a sender, to another entity, a receiver. The sender and receivers may be patients, practitioners, related persons, organizations, or devices. Communication use cases include:
Line 15: Line 15:
  
 
__FORCETOC__
 
__FORCETOC__
 
+
=='''''QDM 5.4 ONLY''''' Communication, Performed==
==Communication, Patient to Provider==
 
  
 
{|border="1" cellpadding="2" cellspacing="0"  
 
{|border="1" cellpadding="2" cellspacing="0"  
Line 23: Line 22:
 
| align="center" style="background:#f0f0f0;"|'''Comment'''
 
| align="center" style="background:#f0f0f0;"|'''Comment'''
 
|-valign="top"
 
|-valign="top"
| row1cell1 | Communication, Patient to Provider
+
| row1cell1 | Communication, Performed
 
| row1cell2 | Communication.status
 
| row1cell2 | Communication.status
 
| row1cell3 | QDM matched to FHIR / QI Core  (the .status metadata allows conformance to the specific QDM datatype context)
 
| row1cell3 | QDM matched to FHIR / QI Core  (the .status metadata allows conformance to the specific QDM datatype context)
Line 30: Line 29:
 
| row2cell2 | Communication.reasonCode
 
| row2cell2 | Communication.reasonCode
 
| row2cell3 | Note - CommunicationRequest in QI Core could be considered but QDM does not differentiate a Communication recommended or ordered, only communication so the mapping assumes the communication has occurred, with or without a response.
 
| row2cell3 | Note - CommunicationRequest in QI Core could be considered but QDM does not differentiate a Communication recommended or ordered, only communication so the mapping assumes the communication has occurred, with or without a response.
 +
|-
 +
| row2cell1 | Category
 +
| row2cell2 | Communication.category
 +
| row2cell3 | QDM matched to FHIR / QI Core
 +
|-
 +
| row2cell1 | Sender
 +
| row2cell2 | Communication.sender
 +
| row2cell3 | QDM matched to FHIR / QI Core
 +
|-
 +
| row2cell1 | Recipient
 +
| row2cell2 | Communication.recipient
 +
| row2cell3 | QDM matched to FHIR / QI Core
 
|-
 
|-
 
| row2cell1 | Negation Rationale
 
| row2cell1 | Negation Rationale
 
| row2cell2 | Communication.notDoneReason
 
| row2cell2 | Communication.notDoneReason
 
| row2cell3 | QDM matched to FHIR / QI Core
 
| row2cell3 | QDM matched to FHIR / QI Core
 +
|-
 +
| row2cell1 | Medium
 +
| row2cell2 | Communication.medium
 +
| row2cell3 | QDM matched to FHIR / QI Core
 +
|-
 +
| row2cell1 | Relevant Period
 +
| row2cell2 | Communication.sent<br> Communication.received
 +
| row2cell3 | QDM matched to FHIR / QI Core; Note - if interoperability is not present, the sending system may not have acknowledgement that the communication was received. In such situation, the QDM relevant period will have no end dateTime.
 
|-
 
|-
 
| row2cell1 | Author dateTime
 
| row2cell1 | Author dateTime
Line 51: Line 70:
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
|}
 
|}
==Communication, Provider to Patient==
+
 
 +
=='''''QDM 5.3 ONLY''''' Communication, Patient to Provider==
  
 
{|border="1" cellpadding="2" cellspacing="0"  
 
{|border="1" cellpadding="2" cellspacing="0"  
Line 58: Line 78:
 
| align="center" style="background:#f0f0f0;"|'''Comment'''
 
| align="center" style="background:#f0f0f0;"|'''Comment'''
 
|-valign="top"
 
|-valign="top"
| row1cell1 | Communication, Provider to Patient
+
| row1cell1 | Communication, Patient to Provider
 
| row1cell2 | Communication.status
 
| row1cell2 | Communication.status
 
| row1cell3 | QDM matched to FHIR / QI Core  (the .status metadata allows conformance to the specific QDM datatype context)
 
| row1cell3 | QDM matched to FHIR / QI Core  (the .status metadata allows conformance to the specific QDM datatype context)
Line 86: Line 106:
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
|}
 
|}
==Communication, Provider to Provider==
+
=='''''QDM 5.3 ONLY''''' Communication, Provider to Patient==
  
 
{|border="1" cellpadding="2" cellspacing="0"  
 
{|border="1" cellpadding="2" cellspacing="0"  
Line 93: Line 113:
 
| align="center" style="background:#f0f0f0;"|'''Comment'''
 
| align="center" style="background:#f0f0f0;"|'''Comment'''
 
|-valign="top"
 
|-valign="top"
| row1cell1 | Communication, Provider to Provider
+
| row1cell1 | Communication, Provider to Patient
 
| row1cell2 | Communication.status
 
| row1cell2 | Communication.status
 
| row1cell3 | QDM matched to FHIR / QI Core  (the .status metadata allows conformance to the specific QDM datatype context)
 
| row1cell3 | QDM matched to FHIR / QI Core  (the .status metadata allows conformance to the specific QDM datatype context)
Line 121: Line 141:
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
|}
 
|}
=='''''Communication, Performed - Consideration for Future Use (QDM 5.4)'''''==
+
=='''''QDM 5.3 ONLY''''' Communication, Provider to Provider==
  
 
{|border="1" cellpadding="2" cellspacing="0"  
 
{|border="1" cellpadding="2" cellspacing="0"  
Line 128: Line 148:
 
| align="center" style="background:#f0f0f0;"|'''Comment'''
 
| align="center" style="background:#f0f0f0;"|'''Comment'''
 
|-valign="top"
 
|-valign="top"
| row1cell1 | Communication, Performed
+
| row1cell1 | Communication, Provider to Provider
 
| row1cell2 | Communication.status
 
| row1cell2 | Communication.status
| row1cell3 | QDM matched to FHIR / QI Core  (the .status metadata allows conformance to the specific QDM datatype context, constrained to "completed")
+
| row1cell3 | QDM matched to FHIR / QI Core  (the .status metadata allows conformance to the specific QDM datatype context)
 
|-
 
|-
 
| row2cell1 | Code
 
| row2cell1 | Code
 
| row2cell2 | Communication.reasonCode
 
| row2cell2 | Communication.reasonCode
| row2cell3 | The reason or justification for the communication.
+
| row2cell3 | Note - CommunicationRequest in QI Core could be considered but QDM does not differentiate a Communication recommended or ordered, only communication so the mapping assumes the communication has occurred, with or without a response.
|-
 
| row2cell1 | Sender
 
| row2cell2 | Communication.sender
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
|-
 
| row2cell1 | Recipient
 
| row2cell2 | Communication.recipient
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the target of the communication.
 
 
|-
 
|-
 
| row2cell1 | Negation Rationale
 
| row2cell1 | Negation Rationale
 
| row2cell2 | Communication.notDoneReason
 
| row2cell2 | Communication.notDoneReason
| row2cell3 | Describes why the communication event did not occur in coded and/or textual form.
+
| row2cell3 | QDM matched to FHIR / QI Core
-
 
| row2cell1 | Relevant Period
 
| row2cell2 | Communication.sent<br>
 
Communication.received<br>
 
| row2cell3 | QDM matched to FHIR
 
 
|-
 
|-
 
| row2cell1 | Author dateTime
 
| row2cell1 | Author dateTime
| row2cell2 | FHIR.provenance.recorded
+
| row2cell2 | Communication.sent
| row2cell3 | QDM matched to FHIR
+
| row2cell3 | QDM addresses authorDatetime as the time the communication is sent.
|-
 
| row2cell1 | Medium
 
| row2cell2 | Communication.medium
 
| row2cell3 | A channel that was used for this communication (e.g. email, fax).
 
 
|-
 
|-
 
| row2cell1 | Related to
 
| row2cell1 | Related to
Line 169: Line 172:
 
| row2cell3 | QDM matched to FHIR / QI Core
 
| row2cell3 | QDM matched to FHIR / QI Core
 
|-
 
|-
| row2cell1 | Sender
+
| row2cell1 | Source
 
| row2cell2 | Communication.sender
 
| row2cell2 | Communication.sender
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
| row2cell3 | The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.
 
|}
 
|}

Latest revision as of 12:35, 15 June 2018

Back to Harmonization of Health Quality Information Models Page

The CQI Workgroup reviewed this content in April 2018 based on QDM version 5.3. The content has been updated to reflect a change in QDM version 5.4. QDM version 5.4 removes the previous QDM datatypes "Communication, Patient to Provider", "Communication, Provider to Patient", and "Communication, Provider to Provider". QDM version 5.4 creates a new QDM datatype, "Communication, Performed". The previous QDM datatype mapping are retained for historical review.

QDM defines Communication as the transmission, receipt, or acknowledgement of information sent from a source to a recipient, such as from one clinician to another regarding findings, assessments, plans of care, consultative advice, instructions, educational resources, etc. It also may include the receipt of response from a patient with respect to any aspect of the care provided. Furthermore, it may include the conveying of information from provider to patient (e.g., results, findings, plans for care, medical advice, instructions, educational resources, appointments). A time and date stamp is required. QDM defines on QDM datatype, Communication, Performed.

FHIR Communication Resource
This resource is a record of a communication. A communication is a conveyance of information from one entity, a sender, to another entity, a receiver. The sender and receivers may be patients, practitioners, related persons, organizations, or devices. Communication use cases include:

  • A reminder or alert delivered to a responsible provider
  • A recorded notification from the nurse that a patient's temperature exceeds a value
  • A notification to a public health agency of a patient presenting with a communicable disease reportable to the public health agency
  • Patient educational material sent by a provider to a patient
  • Non-patient specific communication use cases may include:
  • A nurse call from a hall bathroom
  • Advisory for battery service from a pump

HL7 FHIR Procedure Resource
The boundary between determining whether an action is a Procedure (training or counseling) as opposed to a Communication is based on whether there's a specific intent to change the mind-set of the patient. Mere disclosure of information would be considered a Communication. A process that involves verification of the patient's comprehension or to change the patient's mental state would be a Procedure.


QDM 5.4 ONLY Communication, Performed

QDM Attribute QI Core Metadata Element Comment
Communication, Performed Communication.status QDM matched to FHIR / QI Core (the .status metadata allows conformance to the specific QDM datatype context)
Code Communication.reasonCode Note - CommunicationRequest in QI Core could be considered but QDM does not differentiate a Communication recommended or ordered, only communication so the mapping assumes the communication has occurred, with or without a response.
Category Communication.category QDM matched to FHIR / QI Core
Sender Communication.sender QDM matched to FHIR / QI Core
Recipient Communication.recipient QDM matched to FHIR / QI Core
Negation Rationale Communication.notDoneReason QDM matched to FHIR / QI Core
Medium Communication.medium QDM matched to FHIR / QI Core
Relevant Period Communication.sent
Communication.received
QDM matched to FHIR / QI Core; Note - if interoperability is not present, the sending system may not have acknowledgement that the communication was received. In such situation, the QDM relevant period will have no end dateTime.
Author dateTime Communication.sent QDM addresses authorDatetime as the time the communication is sent.
Related to Communication.basedOn An order, proposal or plan fulfilled in whole or in part by this Communication.
id Communication.id QDM matched to FHIR / QI Core
Source Communication.sender The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.

QDM 5.3 ONLY Communication, Patient to Provider

QDM Attribute QI Core Metadata Element Comment
Communication, Patient to Provider Communication.status QDM matched to FHIR / QI Core (the .status metadata allows conformance to the specific QDM datatype context)
Code Communication.reasonCode Note - CommunicationRequest in QI Core could be considered but QDM does not differentiate a Communication recommended or ordered, only communication so the mapping assumes the communication has occurred, with or without a response.
Negation Rationale Communication.notDoneReason QDM matched to FHIR / QI Core
Author dateTime Communication.sent QDM addresses authorDatetime as the time the communication is sent.
Related to Communication.basedOn An order, proposal or plan fulfilled in whole or in part by this Communication.
id Communication.id QDM matched to FHIR / QI Core
Source Communication.sender The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.

QDM 5.3 ONLY Communication, Provider to Patient

QDM Attribute QI Core Metadata Element Comment
Communication, Provider to Patient Communication.status QDM matched to FHIR / QI Core (the .status metadata allows conformance to the specific QDM datatype context)
Code Communication.reasonCode Note - CommunicationRequest in QI Core could be considered but QDM does not differentiate a Communication recommended or ordered, only communication so the mapping assumes the communication has occurred, with or without a response.
Negation Rationale Communication.notDoneReason QDM matched to FHIR / QI Core
Author dateTime Communication.sent QDM addresses authorDatetime as the time the communication is sent.
Related to Communication.basedOn An order, proposal or plan fulfilled in whole or in part by this Communication.
id Communication.id QDM matched to FHIR / QI Core
Source Communication.sender The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.

QDM 5.3 ONLY Communication, Provider to Provider

QDM Attribute QI Core Metadata Element Comment
Communication, Provider to Provider Communication.status QDM matched to FHIR / QI Core (the .status metadata allows conformance to the specific QDM datatype context)
Code Communication.reasonCode Note - CommunicationRequest in QI Core could be considered but QDM does not differentiate a Communication recommended or ordered, only communication so the mapping assumes the communication has occurred, with or without a response.
Negation Rationale Communication.notDoneReason QDM matched to FHIR / QI Core
Author dateTime Communication.sent QDM addresses authorDatetime as the time the communication is sent.
Related to Communication.basedOn An order, proposal or plan fulfilled in whole or in part by this Communication.
id Communication.id QDM matched to FHIR / QI Core
Source Communication.sender The entity (e.g. person, organization, clinical information system, or device) which was the source of the communication.