This wiki has undergone a migration to Confluence found Here
<meta name="googlebot" content="noindex">

Difference between revisions of "HL7 v3 Requirements"

From HL7Wiki
Jump to navigation Jump to search
Line 44: Line 44:
 
| ''Rationale''  
 
| ''Rationale''  
 
| With HL7 v2, the organization experienced the challenges associated with a specification that was too tightly bound to a particular implementation technology.  One of the objectives for HL7 v3 was to be technology independent.
 
| With HL7 v2, the organization experienced the challenges associated with a specification that was too tightly bound to a particular implementation technology.  One of the objectives for HL7 v3 was to be technology independent.
 +
|-
 +
| '' Methodology''
 +
| To do
 +
|}
 +
 +
 +
{| border="2" cellspacing="0" cellpadding="3" width="600"
 +
| '''Requirement'''
 +
| HL7 v3 specifications must be published in a manner that ensure strict alignment between the "source of truth" and the form rendered to those reviewing and implementing the standards
 +
|-
 +
| ''Rationale''
 +
| Failure for the source of truth to align with what is reviewed (to complete)
 
|-
 
|-
 
| '' Methodology''  
 
| '' Methodology''  
 
| To do  
 
| To do  
 
|}
 
|}

Revision as of 19:06, 18 June 2009

These are high-level HL7 requirements identified by HL7 for the v3 methodology, based on past experience, industry best practice or brought forward by the HL7 membership.

Requirement HL7 standards must be usable in diverse healthcare environments communities throughout the world in circumstances where global consensus down to the detailed 'implementable' level is not (yet) feasible.
Rationale
  • HL7 is international in scope with affiliates from over 30 countries from 6 continents
  • There are variations in healthcare across countries, cultures, medical discipline (e.g. internal medicine vs. psychiatry), type of patient (e.g. human vs. veterinary or pediatric vs. geriatric)
Methodology


Requirement HL7 v3 standards must provide both functional and semantic and interoperability.

I.e. HL7 v3 specifications must standardize both the data structures and mechanics of information exchange as well as the understanding of what that data means and how it is to be used.

Rationale
  • In order for shared information to be safely usable, shared understanding of the meaning of the data is essential
  • Semantic interoperability was often "weak" in HL7 v2, leading to incompatible implementation
Methodology


Requirement HL7 v3 standards should, as much as possible, be independent of an particular implementation technology and should be capable of making use of particular implementation technologies in a standardized way.
Rationale With HL7 v2, the organization experienced the challenges associated with a specification that was too tightly bound to a particular implementation technology. One of the objectives for HL7 v3 was to be technology independent.
Methodology To do


Requirement HL7 v3 specifications must be published in a manner that ensure strict alignment between the "source of truth" and the form rendered to those reviewing and implementing the standards
Rationale Failure for the source of truth to align with what is reviewed (to complete)
Methodology To do