Difference between revisions of "Adverse Event (QDM)"
FEisenberg (talk | contribs) |
Bryn rhodes (talk | contribs) |
||
(5 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
[http://wiki.hl7.org/index.php?title=Harmonization_of_Health_Quality_Information_models Back to Harmonization of Health Quality Information Models Page] <br><br> | [http://wiki.hl7.org/index.php?title=Harmonization_of_Health_Quality_Information_models Back to Harmonization of Health Quality Information Models Page] <br><br> | ||
− | This QDM to QI Core Mapping for the QDM Datatype "Adverse Event" was | + | This QDM to QI Core Mapping for the QDM Datatype "Adverse Event" was reviewed by the CQI WG on March 9, 2018 for QDM 5.3 and updated to QDM 5.4 on June 7, 2018. QDM for "Adverse Event" has no changes between versions 5.3 and 5.4.<br><br> |
QDM defines Adverse Event as any untoward medical occurrence associated with the clinical care delivery, whether or not considered drug related.<br> | QDM defines Adverse Event as any untoward medical occurrence associated with the clinical care delivery, whether or not considered drug related.<br> | ||
+ | <br> | ||
__FORCETOC__ | __FORCETOC__ | ||
+ | ==Adverse Event== | ||
{|border="1" cellpadding="2" cellspacing="0" | {|border="1" cellpadding="2" cellspacing="0" | ||
| align="center" style="background:#f0f0f0;"|'''QDM Attribute''' | | align="center" style="background:#f0f0f0;"|'''QDM Attribute''' | ||
Line 11: | Line 13: | ||
| row1cell1 | Author dateTime | | row1cell1 | Author dateTime | ||
| row1cell2 | FHIR Provenance.recorded | | row1cell2 | FHIR Provenance.recorded | ||
− | | row1cell3 | QDM match to QI Core / FHIR | + | | row1cell3 | QDM match to QI Core / FHIR<br>Note: FHIR Provenance generally addresses the author of the message; the identifier/source of the original resource element is defined by the resource. Individual resource element provenance is summarized in the FHIR W5 Report (http://hl7.org/fhir/w5.html). The AdverseEvent resource does not include a "when.recorded" timing element. Therefore, this mapping uses FHIR provenance.recorded for the QDM attribute for Adverse Event. |
|- | |- | ||
| row2cell1 | Relevant Period | | row2cell1 | Relevant Period | ||
Line 35: | Line 37: | ||
| row2cell3 | QDM matched to QI Core / FHIR | | row2cell3 | QDM matched to QI Core / FHIR | ||
|- | |- | ||
− | | row2cell1 | | + | | row2cell1 | FacilityLocations |
| row2cell2 | AdverseEvent.location | | row2cell2 | AdverseEvent.location | ||
| row2cell3 | QDM matched to QI Core / FHIR | | row2cell3 | QDM matched to QI Core / FHIR |
Latest revision as of 03:42, 28 November 2018
Back to Harmonization of Health Quality Information Models Page
This QDM to QI Core Mapping for the QDM Datatype "Adverse Event" was reviewed by the CQI WG on March 9, 2018 for QDM 5.3 and updated to QDM 5.4 on June 7, 2018. QDM for "Adverse Event" has no changes between versions 5.3 and 5.4.
QDM defines Adverse Event as any untoward medical occurrence associated with the clinical care delivery, whether or not considered drug related.
Contents
Adverse Event
QDM Attribute | QI Core Metadata Element | Comment |
Author dateTime | FHIR Provenance.recorded | QDM match to QI Core / FHIR Note: FHIR Provenance generally addresses the author of the message; the identifier/source of the original resource element is defined by the resource. Individual resource element provenance is summarized in the FHIR W5 Report (http://hl7.org/fhir/w5.html). The AdverseEvent resource does not include a "when.recorded" timing element. Therefore, this mapping uses FHIR provenance.recorded for the QDM attribute for Adverse Event. |
Relevant Period | AdverseEvent.date | QDM references a relevant period:
The Relevant Period references: |
Code | AdverseEvent.suspectEntity.Instance | The QDM code attribute indicates a single code or a member of the value set used to represent the specific quality data element. The code attribute explicitly specifies the value set (or direct referenced code) filter such that the query will retrieve only values defined by the QDM data element value or value set. Previous versions of QDM datatypes implicitly refer to attributes about a set of items that are included in a value set. A QDM data element binds the Adverse Event datatype to a value set (or to a direct reference code) indicating the suspect entity that might have caused the event. The reason is the measures have mostly been focused on Adverse Event as an exclusion criterion. Thus the "code" attribute is most consistent with AdverseEvent.suspectEntity.instance rather than the type of reaction. |
Type | AdverseEvent.reaction | The QDM "Type" attribute definition addresses a value set (or a direct referenced code) that describes the reaction. Hence the mapping of QDM "type" to AdverseEvent.reaction in QI Core. Example - anaphylactic reaction, hives, etc. Greater clarity in definition in QDM descriptions in the CQL-based HQMF and in the QDM publication should be helpful. In the future, QDM might consider adding the FHIR concept AdverseEvent.type (incident, near-miss, unsafe condition) and AdverseEvent.category (AE - adverse event Vs PAE - Potential Adverse Event) |
Severity | AdverseEvent.seriousness | QDM matched to QI Core / FHIR |
FacilityLocations | AdverseEvent.location | QDM matched to QI Core / FHIR |
Recorder | AdverseEvent.recorder | QDM matched to QI Core / FHIR |
id | AdvesreEvent.id | QDM matched to QI Core / FHIR |