== CCD Schematron Rules (Latest Release) == | == CCD Schematron Rules (Latest Release) == | ||
+ | *[http://wiki.hl7.org/images/e/ef/Ccd-schematron-20080709.zip Updated CCD schematron rules - (July 08, 2008)] (zip) | ||
+ | **Added missing constraints for the Product template (templateId 2.16.840.1.113883.10.20.1.53). | ||
+ | == Previous versions == | ||
*[http://informatics.mayo.edu/wiki/images/3/36/Ccd-schema-20071205.zip Updated CCD schematron rules - (Dec 05, 2007)] (zip) | *[http://informatics.mayo.edu/wiki/images/3/36/Ccd-schema-20071205.zip Updated CCD schematron rules - (Dec 05, 2007)] (zip) | ||
**Updates to the following templates. Corrects some xpath context errors. | **Updates to the following templates. Corrects some xpath context errors. | ||
Line 10: | Line 13: | ||
**2.16.840.1.113883.10.20.1.57 | **2.16.840.1.113883.10.20.1.57 | ||
**2.16.840.1.113883.10.20.1.52 | **2.16.840.1.113883.10.20.1.52 | ||
− | |||
− | |||
− | |||
*[http://informatics.mayo.edu/wiki/images/6/66/Ccd-schema-20071022.zip Updated CCD schematron rules - Moved a rule for the vital signs organizer templat out of the vital signs section template. Fixed typeCode validation errors in the Medication series number observation and Patient instruction templates (Oct 22, 2007)] (zip) | *[http://informatics.mayo.edu/wiki/images/6/66/Ccd-schema-20071022.zip Updated CCD schematron rules - Moved a rule for the vital signs organizer templat out of the vital signs section template. Fixed typeCode validation errors in the Medication series number observation and Patient instruction templates (Oct 22, 2007)] (zip) | ||
*[http://informatics.mayo.edu/wiki/images/9/94/Ccd-schema-20071016.zip Updated CCD schematron rules - Fixes various typeCode checking errors and some datatype checking bugs. (Oct 16, 2007)] (zip) | *[http://informatics.mayo.edu/wiki/images/9/94/Ccd-schema-20071016.zip Updated CCD schematron rules - Fixes various typeCode checking errors and some datatype checking bugs. (Oct 16, 2007)] (zip) |
Revision as of 15:24, 9 July 2008
This page contains information about HL7's continuity of care document (CCD).
CCD Schematron Rules (Latest Release)
- Updated CCD schematron rules - (July 08, 2008) (zip)
- Added missing constraints for the Product template (templateId 2.16.840.1.113883.10.20.1.53).
Previous versions
- Updated CCD schematron rules - (Dec 05, 2007) (zip)
- Updates to the following templates. Corrects some xpath context errors.
- 2.16.840.1.113883.10.20.1.18
- 2.16.840.1.113883.10.20.1.34
- 2.16.840.1.113883.10.20.1.57
- 2.16.840.1.113883.10.20.1.52
- Updated CCD schematron rules - Moved a rule for the vital signs organizer templat out of the vital signs section template. Fixed typeCode validation errors in the Medication series number observation and Patient instruction templates (Oct 22, 2007) (zip)
- Updated CCD schematron rules - Fixes various typeCode checking errors and some datatype checking bugs. (Oct 16, 2007) (zip)
- Updated CCD schematron rules - Added correct LOINC code for coverage activity. Increases use of voc.xml for vocabulary validation. Other minor corrections. (Sept 14, 2007) (zip)
- Updated CCD schematron rules - Fixes some bugs in code and unit validation (Aug 03, 2007) (zip)
- Updated CCD schematron rules - includes compiled XSL files (July 20, 2007) (zip)
- Updated CCD schematron rules (April 18, 2007) (zip)
- CCD schematron rules (March 22, 2007) (zip)